something you should to know about solar inverter battery

January 22, 2020 By

Battery is a very important part for  solar inverter , there are two good ways to go about determining battery needs. First, you can determine how long your appliance will run on your battery. The second method is to figure out how much capacity you will need to run a load for a predetermined amount of hours. The issue with reserve capacity is there is not an efficient way to make either of those calculations, so I do not recommend using that rating.    

 Amp-hour rating is the best available specification we have to work with, although it is not without special considerations, but more on that later. The first thing that you want to do when using the Ampere-Hour rating is to convert your wattage and runtime requirement into watt-hours, and then to amp-hours.    

For specifics on solar batteries visit that page

Take notice that amp-hour ratings have a duration associated with them. Be sure to get that duration before going any further with your battery calculations. An amp-hour rating at 20 hours is the most common rating. That means the rating is good for a discharge taking place over a 20 hour period of time, and your amp-hour capacity is reduced if the discharge occurs in less time, this is referred to as Peukert’s law.     It is important to keep in mind that as useful as these ratings can be if applied correctly, battery capabilities are based on a chemical reaction involving several factors within the battery. In other words, it is not a simple linear calculation. A heavy load can cause an instant low voltage shutdown due to the resulting amount of internal resistance. This instant drop in battery voltage can cause some confusion because after the shutdown occurs, the heavy load is essentially removed and the voltage rises right back up.   

 If you do run into problems ALWAYS check your connections, make sure your battery is completely charged and have the health of your battery tested. Battery maintenance is essential for ensuring longevity and peak day-to-day performance. Undersized cables, extreme temperatures, fluid levels and sulfation build-up can all hurt battery performance.    

 Without the correct amount of battery preparation, an exciting inverter set up can quickly turn into a frustrating experience. Hopefully you are now equipped with a better understanding of how batteries work, and in specific, how battery ratings apply to your inverter.      

Sometimes you can also use your spare battery, the key is to understand what your real needs are spare battery. I met them expect to have a spare battery for the whole house, but that they generally consume 150 kilowatts hours of energy every day people. It probably will not happen! Small inverter might just meet a real emergency situation your needs!     

Why you can not use spare battery grid-connected parallel system that allows you during a power outage, has the power? I understand that if your system is always fascinated by it is sure to encounter difficulties due to excessive load power, but if you installed a break, and then let your spare batteries, solar panels and grid panels between no chance of overloading when your system is such that the decision fails electricity supplier. Your system does not try to feed the entire grid, because you have to disconnect your front panels enabled.

Source: Free Articles from ArticlesFactory.com